-40%

CONTEC Digital Touch 12 Channel Lead ECG Machine EKG Electrocardiograph Printer

$ 395.47

Availability: 100 in stock
  • Return shipping will be paid by: Buyer
  • Brand: CONTEC
  • All returns accepted: Returns Accepted
  • Model: ECG1212G
  • Condition: New
  • Number of Channels: 12
  • Number of Leads: 12
  • Country/Region of Manufacture: China
  • Refund will be given as: Money Back
  • ECG & EKG Machine Type: Electrocardiograph
  • Features: Printer
  • Item must be returned within: 60 Days
  • MPN: 69450401
  • Intended Use/Discipline: Cardiology
  • Restocking Fee: No
  • Operation: Digital

    Description

    ECG1212G Touch Digital 12 channel ECG Machine Electrocardiograph,PC Software
    Introduction
    The device is an electrocardiograph which can collect 12-lead ECG signal simultaneously and print ECG waveform with thermal printing system. It features in, recording and displaying ECG waveform in auto / manual mode; measuring, analyzing and diagnosing ECG waveform parameters automatically; prompting for “Lead off” and “Lack of paper”; optional interface language (Chinese / English, etc.); built-in lithium battery, AC / DC; selecting rhythm lead freely to observe abnormal heart rhythm; case database management.
    Functions
    1)Adopt 10.1'' high-resolution color LCD, operate by full-touch screen and function bu ttons, convenient to use.
    2)Sync collection for 12-lead ECG, support 12-lead and Cabrera-lead waveform display. Get high-quality ECG waveform via power frequency filter (50 / 60 Hz), baseline filter and EMG filter (25 / 35 Hz) of ECG signal.
    3)Display 3 / 6 / 12 - lead ECG waveform, HR value, print mode, sensitivity, paper speed, filter state, clock, battery power, background grid, measured parameter and interpretation, etc. on one screen, and with prompt functions for lead - off, overload and system working state.
    4)Power supply: AC / DC (which can adapt AC 50 / 60Hz), with built-in rechargeable lithium battery, charging circuit, perfect over-current and over-voltage protection circuit.
    5)In optimal DC state, up to 10-hour standby time, continuous print for more than 3-hour, which meets the requirements of visiting a patient at home and body examination.
    6)Built-in thermal printer, support multiple printing modes and formats, such as, auto M × N, M × N + 1, M × N + 2, rhythm M line and manual, etc. The contents including time, paper speed, sensitivity, calibration signal, lead name, filter state and patient information can be printed. The waveform length printed, measurement parameter output, diagnosis conclusion, superimposed QRS waveform, histogram, trend chart and interval list, etc. can be set. With the print functions (timing print and auto-print for arrhythmia, etc.), which meet different requirements.
    7)With the functions of auto-measurement and auto-interpretation for routine ECG parameters, provide measured results and auto-diagnosis conclusions for HR, PR interval, P Duration, QRS Duration, QT / QTc interval, P / QRS / T Axis, R (V5), S (V1), R (V5) + S (V1) amplitude, etc. which reduces the doctor’s burden.
    8)Built-in memory stores 4000 cases (data saving time: 10 s) at least, convenient for case review and statistic.
    9)Historical cases can be reviewed, inquired, modified, transmitted, printed, lead corrected, the cases can also be exported to other electronic file formats (dat, pdf, xml, bmp, jpeg, etc.)
    10)Chinese / English operating interface, the report in corresponding language can be printed; built-in virtual keyboard, support Chinese / English input method.
    11)Support external USB standard keyboard, mouse, scanner and printer.
    Performance
    1)Input mode: floating and defibrillation protection
    2)Lead: standard 12-lead
    3)Patient leak current: < 10 µA
    4)Input impedance: ≥ 2.5 MΩ
    5)Frequency response:
    Nominal input amplitude    Input frequency and waveform    Relative output response
    1.0    0.67 Hz ~ 40 Hz, sinusoidal    ±10 %a
    0.5    40 Hz ~ 100 Hz, sinusoidal    +10 %, -30 %a
    0.25    100 Hz ~ 150 Hz, sinusoidal    +10 %, -30 %a
    0.5    150 Hz ~ 500 Hz, sinusoidal    +10 %, -100 %a
    1.5    ≤1 Hz ,200 ms, triangular    +0 %, -10 %b
    a relative to 10 Hz output   b relative to 200 ms output
    6)Time constant: ≥ 3.2 s
    7)CMRR: > 105 dB
    8)Filter: power frequency (AC 50 / 60 Hz), EMG (25 Hz / 35 Hz (-3 dB)) and baseline drift
    9)Recording mode: thermal printing system
    10)Paper size: 210 mm (W) × 20 m (L), high-speed thermal paper
    11)Paper speed: 12.5 mm/s, 25 mm/s, 50 mm/s, error: ± 5 %
    12)Gain (sensitivity): 5, 10, 20 mm / mV, accuracy: ± 2 %
    Standard sensitivity: 10 mm/mV ± 0.2 mm/mV
    13)Record mode: auto, rhythm and manual record
    14)Measurement parameters: HR, P - R interval, P Duration, QRS Duration, T Duration, Q - T interval, Q - Tc, P Axis, QRS Axis, T Axis, R (V5) amplitude, S (V1) amplitude, R (V5) + S (V1) amplitude
    15)Safety class: class I, defibrillation-proof type CF applied part
    16)Polarizing voltage: ± 610 mV
    17)Noise level: ≤ 12 µVp-p
    18)Sampling frequency for ECG signal input: 32 kHz
    19)Sampling frequency for waveform data processing: 1 kHz
    20)Sampling accuracy: 24 - bit
    21)Minimum detection signal: a 10 Hz, 20 µV (peak - peak value) sinusoidal signal can yield a visual recorded deflection.
    22)Pacemaker detection channel: II
    23)Accuracy of input signal reproduction: ± 5 %
    24)Amplitude quantization: ≤ 5µV/LSB
    25)Time deviation in each channel: <100 µs
    26)Power supply:
    AC: 100V ~ 240V (50 / 60 Hz)
    DC: 14.8 V / 5200 mAh rechargeable lithium battery
    27)Degree of protection against ingress of liquid: IPX0
    28)Working mode: continuous operation
    Accessories
    Standard:
    One lead cable
    One limb electrode
    One chest electrode
    One thermal recording paper
    One power cord
    One earth wire
    One User Manual
    Physical characteristic
    Operating:
    a) Environment temperature: 5 ℃ ~ 40 ℃
    b) Relative humidity: 25 % ~ 95 % (non - condensing)
    c) Atmospheric pressure: 700 hPa ~ 1060 hPa
    Transport and storage:
    a) Environment temperature: - 20 ℃ ~ + 55 ℃
    b) Relative humidity: ≤ 95 %
    c) Atmospheric pressure: 500 hPa ~ 1060 hPa
    Dimension: 340 mm (L) × 320 mm (W) × 86 mm (H)
    Weight: 5 kg
    Shipping
    * Clearance: we will ship your item(s) to your PayPal confirmed address.Please leave me your clear address,telephone,postal code.
    * It is the buyers' responsibility to consider duties, taxes and other extra charges by the government in your respective country.
    * All items will be dispatched within 2 business day.
    * The item will be declared as lower value for shipping only.We'd like to cooperate with you and declare the value of it as you want us to, so that it is more easier for you to clear the custom.
    Terms of Sale
    There are not extra taxes, VAT or other unmentioned payment. You pay us with goods subtotal + shipping cost (not include duties). But you need to pay for the import duties in case that occurred for certain goods, or you may kindly give us some suggestions about that,we promise to do our best to help you!
    Return - After service
    We offer 60 days return policy. 100% satisfaction is our goal!
    1.All items are brand new ,with 1 years warranty.
    2.If you have a defective item, you want to return or discount. Please contact us within 2 days from you receive the shipment.
    3.We will refund the money to you when we get the return items or replace item for you.
    4. All return items must be returned with it's original packaging and accessories. Customer is responsible for shipping charges on returned items.
    Buy safe Products
    The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE:
    The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies.If the item is subject to FDA regulation,We will verify your status as an authorized purchaser of this item before shipping of the item.If you have questions about legal obligations regarding sales of medical devices, you should consult with the FDA's Center for Devices and Radiological Health.
    The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 197923, and certified by FDA of United States and CE,TUV of Europe.The  Fingertip Pulse Oximeter that is FDA 510K Approved
    About Us
    Contec Medical Systems focusing on research, manufacture and distribution of medical instruments,was founded in 1992 as a high-tech company.
    At present there are more than 1200 employees in our company.Our product line covers a wide range of 13 categories.Most of the domestic hospitals are our customers.Contec hopes to cooperate with international companies to supply more innovative design and advanced technology products.
    We sincerely welcome you to become one of our global partners.We are looking forward to establishing a successful business relationship with you.